Description
My friend, welcome to our store, if you need other models of this product, please contact me, I will send the product link for you to buy!
Whatsapp+8619330216441
Medical Hospital Health Testing Self Service Kiosk Health Booth Telemedicine Kit Devices Wifi Telemedicine
Related products
Products Description
Model No. |
SK-T8X | ||
Level |
Class I, type B | ||
Height |
Height sensor |
Ultrasound probe(Buy from USA) | |
Accuracy |
0.01cm | ||
Weight |
BMI |
Automatic calculation | |
Loadcell |
500kg | ||
Accuracy |
±0.1kg | ||
Body composition analysis |
Frequencies |
5kHz/50kHz/250kHz/500kHz | |
Measurement |
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism | ||
Measurement current |
90μA or below | ||
Electrode material |
Electroplating material | ||
Measurement range |
75.0~1,500.00Ω(0.1Ω unit) | ||
Measurement location |
Trunk, 4 limbs | ||
Body temperature |
Test Method |
Infrared wireless hand-held temperature gun | |
Accurate to |
0.1 ℃ | ||
Operation & storage temperature |
10~40℃, 0~50℃ | ||
Operation & storage humidity |
≤85% | ||
Power |
DC 9V | ||
Dimension |
150*75*40mm | ||
Weight |
180g | ||
Human temperature range |
32.0~42.5℃ | ||
Object temperature range |
0~100℃ | ||
Accuracy |
≤±0.3℃ | ||
Power consumption |
≤120mw | ||
Detection distance |
5 to 8 cm | ||
Auto-off |
after 15 seconds | ||
Blood pressure monitor |
Blood pressure range |
“(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm” | |
Storage capacity |
100 pcs of record | ||
Accuracy |
Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2% | ||
Power |
AC 100-240V,50-60Hz,1.6-0.8A | ||
Operation temperature & humidity |
5℃~40℃ 15%RH~80%RH | ||
Transport & storage temperure & humidity |
-20℃~55℃ <93%RH | ||
Operation atmospheric pressure |
80Kpa~106Kpa | ||
Transport & storage atmospheric pressure |
50Kpa~106Kpa | ||
Dimension |
471.5mm(L)*402.0mm(W)*309.0mm(H) | ||
Electric shock protection |
Class I, type B | ||
Device weight |
8kg | ||
Arm circumference |
17-42cm | ||
Blood oxygen |
Probe |
Dual-wavelength LED | |
Wave length |
Red light: 663nm, Infrared: 890nm | ||
Range |
35%~100% | ||
Power of maximum light output |
≤2mW | ||
Blood oxygen rate accuracy |
Range: 70%~100%, ±2% | ||
Pulse rate accuracy |
Range: 30~250bpm, ±2% | ||
Operation temperature |
5℃~40℃ | ||
Operation humidity |
15%~95% | ||
Atmospheric pressure |
70kpa~106kpa | ||
Power input |
From main device by RS232 | ||
ECG |
Leads |
6 or 12 leads | |
Collection |
Syhchronization | ||
Calibration voltage |
1mV±5% | ||
Polarization resistance voltage |
±300mV | ||
Sensitivity |
5, 10, 20(mm/mV) | ||
Input impedance |
≥5MΩ | ||
Input loop current |
<0.05uA | ||
Heart rate range |
20-300bmp/min | ||
Noise level |
≤15uVp-p | ||
Filtering |
EMG Filtering | ||
Baseline filtering | |||
AC filtering | |||
Common mode rejection ratio |
>90dB | ||
Time constant |
≥3.2s | ||
Frequency response |
0.05Hz~150Hz(-3.0dB/+0.4dB) | ||
Rhythmic lead |
Any leads optional | ||
Base line adjustment |
Automatic | ||
Patient leak current |
<10uA(220V-240V) | ||
Patient auxiliary current |
≤0.1uA(DC) | ||
Safety standard |
IEC II/CF | ||
Sampling frequency |
500Hz | ||
Electrode |
Chest electrodes and limb electrodes adopt international colors, each matches different color | ||
“Blood glucose Uric acid Total cholesterol” |
Measurement range |
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) | |
Measurement time |
blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S | ||
Reference for normal |
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L | ||
Uric acid of male: 0.21~0.43mmol/L | |||
Uric acid of female: 0.16~0.36mmol/ | |||
Uric acid of children: 0.12~0.33mmol/L | |||
Total cholesterol: 2.86~5.98mmol/L | |||
Accuracy |
±0.3(test by standard resistance slip) | ||
Display |
mmol/Lx and time display | ||
Inbuilt battery |
3V Lithium battery | ||
Lipid profile |
Sample type |
Capillary vessel whole blood sample, venous blood | |
Type |
Total cholesterol | ||
HDL: High density Lipoprotein | |||
TG: Triglyceride | |||
LDL: Low density Lipoprotein(By calculation) | |||
Method |
Enzymatic colorimetric analysis | ||
Mesurement range |
Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L) | ||
Triglyceride: 70-600mg/dL(0.8-6.8mmol/L) | |||
High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L) | |||
Test period |
About 120 seconds | ||
Calibration |
Plasma or similar product | ||
Sample volume |
5 microlitre | ||
Blood glucose |
Sample type |
Capillary vessel whole blood sample | |
Measurement range |
10-600 mg/dL(0.6-33.3mmol/L) | ||
Sample volume |
0.3 microlitre | ||
Test period |
3 seconds | ||
Calibration |
Plasma or similar product | ||
HCT range |
20-60% | ||
RFID |
Standard: IS0/IEC 15693 | ||
Read/write distance: 2cm | |||
Antenna: integrated | |||
Frequence: 13.56MHz | |||
Measurement theory for blood glucose |
Electrochemistry, Optical spectrum | ||
Storage capacity |
200 | ||
Operation temperature |
“Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)” | ||
Operation humidity |
10-90% | ||
Storage temperature |
2-30℃(36-80℉) | ||
Display |
LCD | ||
Dimension |
61*109*23(mm) | ||
Weight |
77.5(with battery)±1g | ||
Battery life time |
>1000 cycle use | ||
Advertisement screen |
Display screen |
19″ LCD screen, visible under sunshine | |
Opertion screen |
Display screen |
17″ LCD screen | |
Dimension |
Package dimension: |
121(L)*190(H)*140(W)cm | |
Machine dimension: |
242(H)*174(L)*61(W)cm | ||
Inbuilt PC and processor |
Gifa® industrial board, Intel 4 core CPU | ||
Operation system |
Windows 7 32bits OS | ||
A4 printer |
HP-P1106 | ||
Data output port |
TCP/IP | ||
Voltage |
220 AC (50Hz/60Hz) | ||
Power consumption |
100W (Max.) | ||
Operation and storage temperature |
5℃~45℃(-10℃~+60℃) | ||
Machine weight |
76kg |
Model No. |
SK-T8X | ||
Level |
Class I, type B | ||
Height |
Height sensor |
Ultrasound probe(Buy from USA) | |
Accuracy |
0.01cm | ||
Weight |
BMI |
Automatic calculation | |
Loadcell |
500kg | ||
Accuracy |
±0.1kg | ||
Body composition analysis |
Frequencies |
5kHz/50kHz/250kHz/500kHz | |
Measurement |
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism | ||
Measurement current |
90μA or below | ||
Electrode material |
Electroplating material | ||
Measurement range |
75.0~1,500.00Ω(0.1Ω unit) | ||
Measurement location |
Trunk, 4 limbs | ||
Body temperature |
Test Method |
Infrared wireless hand-held temperature gun | |
Accurate to |
0.1 ℃ | ||
Operation & storage temperature |
10~40℃, 0~50℃ | ||
Operation & storage humidity |
≤85% | ||
Power |
DC 9V | ||
Dimension |
150*75*40mm | ||
Weight |
180g | ||
Human temperature range |
32.0~42.5℃ | ||
Object temperature range |
0~100℃ | ||
Accuracy |
≤±0.3℃ | ||
Power consumption |
≤120mw | ||
Detection distance |
5 to 8 cm | ||
Auto-off |
after 15 seconds | ||
Blood pressure monitor |
Blood pressure range |
“(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm” | |
Storage capacity |
100 pcs of record | ||
Accuracy |
Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2% | ||
Power |
AC 100-240V,50-60Hz,1.6-0.8A | ||
Operation temperature & humidity |
5℃~40℃ 15%RH~80%RH | ||
Transport & storage temperure & humidity |
-20℃~55℃ <93%RH | ||
Operation atmospheric pressure |
80Kpa~106Kpa | ||
Transport & storage atmospheric pressure |
50Kpa~106Kpa | ||
Dimension |
471.5mm(L)*402.0mm(W)*309.0mm(H) | ||
Electric shock protection |
Class I, type B | ||
Device weight |
8kg | ||
Arm circumference |
17-42cm | ||
Blood oxygen |
Probe |
Dual-wavelength LED | |
Wave length |
Red light: 663nm, Infrared: 890nm | ||
Range |
35%~100% | ||
Power of maximum light output |
≤2mW | ||
Blood oxygen rate accuracy |
Range: 70%~100%, ±2% | ||
Pulse rate accuracy |
Range: 30~250bpm, ±2% | ||
Operation temperature |
5℃~40℃ | ||
Operation humidity |
15%~95% | ||
Atmospheric pressure |
70kpa~106kpa | ||
Power input |
From main device by RS232 | ||
ECG |
Leads |
6 or 12 leads | |
Collection |
Syhchronization | ||
Calibration voltage |
1mV±5% | ||
Polarization resistance voltage |
±300mV | ||
Sensitivity |
5, 10, 20(mm/mV) | ||
Input impedance |
≥5MΩ | ||
Input loop current |
<0.05uA | ||
Heart rate range |
20-300bmp/min | ||
Noise level |
≤15uVp-p | ||
Filtering |
EMG Filtering | ||
Baseline filtering | |||
AC filtering | |||
Common mode rejection ratio |
>90dB | ||
Time constant |
≥3.2s | ||
Frequency response |
0.05Hz~150Hz(-3.0dB/+0.4dB) | ||
Rhythmic lead |
Any leads optional | ||
Base line adjustment |
Automatic | ||
Patient leak current |
<10uA(220V-240V) | ||
Patient auxiliary current |
≤0.1uA(DC) | ||
Safety standard |
IEC II/CF | ||
Sampling frequency |
500Hz | ||
Electrode |
Chest electrodes and limb electrodes adopt international colors, each matches different color | ||
“Blood glucose Uric acid Total cholesterol” |
Measurement range |
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) | |
Measurement time |
blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S | ||
Reference for normal |
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L | ||
Uric acid of male: 0.21~0.43mmol/L | |||
Uric acid of female: 0.16~0.36mmol/ | |||
Uric acid of children: 0.12~0.33mmol/L | |||
Total cholesterol: 2.86~5.98mmol/L | |||
Accuracy |
±0.3(test by standard resistance slip) | ||
Display |
mmol/Lx and time display | ||
Inbuilt battery |
3V Lithium battery | ||
Lipid profile |
Sample type |
Capillary vessel whole blood sample, venous blood | |
Type |
Total cholesterol | ||
HDL: High density Lipoprotein | |||
TG: Triglyceride | |||
LDL: Low density Lipoprotein(By calculation) | |||
Method |
Enzymatic colorimetric analysis | ||
Mesurement range |
Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L) | ||
Triglyceride: 70-600mg/dL(0.8-6.8mmol/L) | |||
High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L) | |||
Test period |
About 120 seconds | ||
Calibration |
Plasma or similar product | ||
Sample volume |
5 microlitre | ||
Blood glucose |
Sample type |
Capillary vessel whole blood sample | |
Measurement range |
10-600 mg/dL(0.6-33.3mmol/L) | ||
Sample volume |
0.3 microlitre | ||
Test period |
3 seconds | ||
Calibration |
Plasma or similar product | ||
HCT range |
20-60% | ||
RFID |
Standard: IS0/IEC 15693 | ||
Read/write distance: 2cm | |||
Antenna: integrated | |||
Frequence: 13.56MHz | |||
Measurement theory for blood glucose |
Electrochemistry, Optical spectrum | ||
Storage capacity |
200 | ||
Operation temperature |
“Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)” | ||
Operation humidity |
10-90% | ||
Storage temperature |
2-30℃(36-80℉) | ||
Display |
LCD | ||
Dimension |
61*109*23(mm) | ||
Weight |
77.5(with battery)±1g | ||
Battery life time |
>1000 cycle use | ||
Advertisement screen |
Display screen |
19″ LCD screen, visible under sunshine | |
Opertion screen |
Display screen |
17″ LCD screen | |
Dimension |
Package dimension: |
121(L)*190(H)*140(W)cm | |
Machine dimension: |
242(H)*174(L)*61(W)cm | ||
Inbuilt PC and processor |
Gifa® industrial board, Intel 4 core CPU | ||
Operation system |
Windows 7 32bits OS | ||
A4 printer |
HP-P1106 | ||
Data output port |
TCP/IP | ||
Voltage |
220 AC (50Hz/60Hz) | ||
Power consumption |
100W (Max.) | ||
Operation and storage temperature |
5℃~45℃(-10℃~+60℃) | ||
Machine weight |
76kg |
All Posts and Banners,Logos,Images belong to its respective owner & owners.©Copyright 2024.All Rights Reserved!
Disclaimer : This advertisement and the information related to it are provided and maintained by the advertiser. Dkfon.com is not responsible and can not guarantee the accuracy or completeness of this advertisement. Please note that every advertisement for rent or for sale should at a minimum, display the energy performance rating of the property. See our Flats and Housing Posting Rules for more information.
Avoid scams: Signs of fraud: wire transfer, money orders, cashier checks, payment via gift cards, shipping, escrow, "transaction protection", "guarantee". Be safe by dealing locally.
BUY FROM DKFON.COM OFFICIAL AGENT WITH WARRANTY.WHATSAPP/CALL:+90 546 884 4323
If you want to buy,sell,rent,exchange secure and avoid scam please whatsapp/email to our intl sales team email/whatsapp number for quick legal agreement and start secure process with us.
Reviews
There are no reviews yet.