Description
Model | PD30-CRL-DCF | PD50-CRL-DCF | ||||
Heating | Heating Capacity Range (kW) | 7.4~15.9 | 11.7~23.5 | |||
Heating Input Range (kW) | 1.5~3.9 | 2.4~6.4 | ||||
Current Range (A) | 7.5~19.3 | 4.8~12.8 | ||||
COP Range | 3.69~4.9 | 3.67~4.88 | ||||
Cooling | Cooling Capacity Range (kW) | 4.9~8.9 | 8.2~14.8 | |||
Cooling Input Power(kW) | 1.5~3.7 | 2.5~6.0 | ||||
Current Range (A) | 7.3~18.1 | 5.0~12.0 | ||||
EER Range | 2.41~3.27 | 2.47~3.28 | ||||
DHW | Heating Capacity Range (kW) | 5.9~12.8 | 9.4~19.8 | |||
Heating Input Range (kW) | 1.5~4.2 | 2.4~6.8 | ||||
Current Range (A) | 7.3~19.7 | 4.8~13.6 | ||||
COP Range | 3.05~3.93 | 2.91~3.92 | ||||
Refrigerant | R410A | |||||
Power Supply | 230V/1Ph/50-60Hz | 380V/3Ph/50-60Hz | ||||
Working Area | -30~43℃ | |||||
Water Circulation (m³/H) | 2.73 | 4.04 | ||||
Water Pressure Drop (kPa) | 25 | 30 | ||||
IP Grade (Level of protection) | IPX4 | IPX4 | ||||
Anti-electric Shock Rate | I | I | ||||
Noise (dB(A)) | ≤53 | ≤58 | ||||
Net Weight/Gross Weight(kg) | 150/160 | 180/190 | ||||
Water Connection | G1′ | G1′ | ||||
Heating Side Water Connection | G1′ | G1′ | ||||
Hot Water Side Water Connection | G1′ | G1′ | ||||
Body Size(W*D*H) (mm) | 1076×480×800(indoor)/ 836×580×306(outdoor) | 1100×480×1330(indoor)/ 836×520×306(outdoor) | ||||
ErP Level (35°C) | A++ | A++ | ||||
ErP Level (55°C) | A+ | A+ | ||||
Compressor Type/QTY | Twin-rotary/1 | |||||
Condensor Type | Plate tank | |||||
Fan Motor | DC type | |||||
Defrosting | By four-way valve | |||||
Throttle Device | Electronic expansion valve | |||||
Water Head(m) | 6m | 8m | ||||
Expansion tank(L) | 5 | |||||
Electric heater(kW) | 3 | |||||
Operating Water Temp. (℃) DHW | 9~60℃ | |||||
Operating Water Temp. (℃) Heating | 9~50℃ | |||||
Operating Water Ttemp.(℃) Cooling | 7~35℃ | |||||
Remark: Heating working condition: Inlet/Outlet water temp. 30℃/ 35℃, Dry/Wet bulb temp. 7℃/6℃. Cooling working condition: Inlet/Outlet water temp. 12℃/ 7℃, Dry/Wet bulb temp. 24℃. DHW working condition: Inlet/Outlet water temp. 15℃/55℃, Dry/Wet bulb temp. 7℃/6℃. Note: The data above is for reference only. Please refer to the nameplate on the unit for more specific data. |
A: We are R&D and manufacturer factory with 30,000 sq meters modern factory.
A: Yes. We can produce Pool World standard products under clients’ brand, modify the products to satisfy client’s personalized requirements and work together with clients to design and produce a totally new products.
Q: How long is your Heat Pump delivery time?
A: Generally it is 1-5 working days if the goods are in stock. or it is 15-25 working days if the goods are not in stock, it is according to quantity.
Q: How about the channel management?
Q: How long can I get the salesman’s contact after sending the inquiry?
A: The customer service will check the inquiry message every day and match the right sales manager for every inquiry. The sales manager will contact you within 12 hours after receiving the sales leads. Please complete your email and contact number in your personal information so that we can contact you soon.
Reviews
There are no reviews yet.